Check SiBE061121129 Service Diagnosis5.11 Outdoor Fan System CheckCheck No.19 DC motor5.12 Main Circuit Short CheckCheck No.20Note: Check to make sure that the voltage between (+) and (–) of the diode bridge (DB1) is approx.0 V before checking. Measure the resistance between the pins of the DB1 as below. If the resistance is ∞ or less than 1 kΩ, short circuit occurs on the main circuit.(R15001)YESYESNONOOutdoor fan system is functioning.Check the outdoor fan system.Go to Check No. 16.Outdoor fan running?Fan motorlead wire connectordisconnected? Reconnect the connector.(–) terminal of the tester(in case of digital,(+) terminal) ~ (2, 3) + (4) ~ (2, 3) – (1)(+) terminal of the tester(in case of digital,(–) terminal) + (4) ~ (2, 3) – (1) ~ (2, 3)Resistance is OK. several kΩ~ several MΩ ∞ ∞ several kΩ~ several MΩResistance is NG. 0 Ω or ∞ 0 0 0 Ω or ∞(R12035)Tester– ~ ~ +1234–+