SiBE061121 Outdoor Unit - RXG50K2V1BRemoval Procedure 2043.3 Removal of Electrical BoxProcedure Warning Be sure to wait for 10 minutes or more after turning off all powersupplies before disassembling work.Step Procedure Points1 Remove the 2 screwsof the shield plate.Preparation Remove the top panel andthe front panel according tothe “Removal of OuterPanels”.2 Slide the shield plateupward to unfasten thehook on the bottom left,and then remove theshield plate.3 Disconnect the 2 powersupply cables and theearth wire.(R5266)Shieldplate(R5267)(R5268)Earth wire