12 Technical dataInstallation and operating instructions67Gas Combi UnitFloor-standing gas condensing boiler with integrated heat storage008.1543899_02 – 04/2019 – EN12 Technical data12.1 Basic data12.1.1 GCU compact 3xxType (1)(22) GCU compactIndividual Unit 315 / 315 Biv 320 / 320 BivPermitted ambient temperature °C 1 - 40Total storage capacity litres 294Net weight (11)(22) kg 76 / 78Total filled weight kg 370 / 372Dimensions (W × D × H) cm 59.5 × 61.5 × 189.5Maximum permissible storage water temperature °C 85Standby heating power kWh/24 h 1.5Drinking water heat exchanger (stainless steel)Water capacity heat exchanger litres 18.6Heat exchanger surface area m2 3.8Max. operating pressure for potable water PMW (14)(22) bar 6Storage tank charging heat exchanger (stainless steel)Water capacity heat exchanger litres 8.7Heat exchanger surface area m2 1.8Pressurised solar heat exchanger (stainless steel)Water capacity heat exchanger litres — / 3.9Heat exchanger surface area m2 — / 0.7Pipe connectionsCold and hot water inches 1" outer threadHeating feed and return flow inches 1" outer threadThermal performance data (sanitary)Output characteristic figure NL in accordance with DIN 4708(23) 2.0 2.1D value (specific water flow) conforms to EN 13203(24)(15)(22) l/min 22 23Continuous output QD according to DIN 4708 kW 15 20Max. draw-off rate for a period of 10 min at(TKW = 10 °C / TWW = 40 °C / TSP = 60 °C)litres 19 20Hot water quantity without reheating with up to 15 l/min draw-offrate(TKW = 10 °C / TWW = 40 °C / TSP = 60 °C)litres 200Hot water quantity with reheating at nominal output and 15 l/minat draw-off rate(TKW = 10 °C / TWW = 40 °C / TSP = 60 °C)litres 300 350Short-term water quantity in 10 min(25) litres 190 200Electrical systemMaximum electrical power consumption(without/with heating circulation pump) (9)(22)W 36 / 76 38 / 98Max. electric power consumption in "Standby" operating mode W 3.1Voltage supply (8)(22) ~230 V, 50 HzDegree of protection (10)(22) IP X0BTab. 12-1 Technical data for GCU compact 3xx(22) Value in brackets corresponds to item number in Fig. 12-1(23) Reheating with nominal output, inflow temp. TV = 80 °C, starting storage tank temp. TSP = 65 °C, cold water temp.TKW = 10 °C, hot water temp. TWW = 45 °C.(24) The spec. water flow acc. to EN 13203 is the domestic water flow at an average temperature increase of 30 K, which theGCU compact can supply if two draw-off procedures each of 10 minutes duration are performed one after the other, assum-ing a charging temp. of 65 °C. A delay of 20 minutes between the two draw-off procedures is usually assumed. TheGCU compact achieves this value with even shorter waiting periods.(25) Reheating with nominal output, starting storage tank temp. TSP = 60 °C, cold water temp. TKW = 10 °C, hot water temp.TWW = 40 °C.