EDUS041011 Electric CharacteristicsRoom Air Conditioners J-Series 2310. Electric Characteristics3D066179BRepresentative Unit Combination Power Supply COMP OFM IFMIndoor Unit Outdoor Unit Hz-Volts Voltage Range MCA MOP RLA W FLA W FLAFTKS09JEVJU RKS09JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 4.4 15 3.7 33 0.19 40 0.2060-230 3.4 0.17 0.18FTKS12JEVJU RKS12JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 4.4 15 3.7 33 0.19 40 0.2060-230 3.4 0.17 0.18FTXS09JEVJU RXS09JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 4.3 15 3.7 33 0.19 40 0.2060-230 3.3 0.17 0.18FTXS12JEVJU RXS12JEVJU 60-208 MAX. 60Hz 253VMIN. 60Hz 187V 5.2 15 4.4 33 0.19 40 0.2060-230 4.0 0.17 0.18Symbols: Note:MCA : MIN. CIRCUIT AMPS (A) 1. Maximum allowable voltage variation between phases is 2%.2. Select wire size based on the larger value of MCA.3. Instead of fuse, use circuit breaker.4. Be sure to install a ground leak detector. (One that can handlehigher harmonics.)(This unit uses an inverter, which means that it must use a groundleak detector capable handling high harmonics in order to preventmalfunctioning of the ground leak detector itself.)MOP : MAX OVERCURRENT PROTECTIONRLA : RATED LOAD AMPS (A)OFM : OUTDOOR FAN MOTORIFM : INDOOR FAN MOTORFLA : FULL LOAD AMPS (A)W : FAN MOTOR RATED OUTPUT (W)