SiENBE07-618_C Main FunctionsFunction and Control 251.8 HOME LEAVE OperationOutline HOME LEAVE operation is a function that allows you to record your favorite set temperatureand airflow rate. You can start your favorite operation mode simply by pressing the [HOMELEAVE] button on the remote control.Detail 1. Start of FunctionThe function starts when the [HOME LEAVE] button is pressed in cooling mode, heating mode(including POWERFUL operation), or while the operation is stopped. If this button is pressed inPOWERFUL operation, the POWERFUL operation is canceled and this function becomeseffective. The [HOME LEAVE] button is ineffective in dry mode and fan mode.2. Details of FunctionA mark representing HOME LEAVE is indicated on the display of the remote control. The indoorunit is operated according to the set temperature and airflow rate for HOME LEAVE which werepre-set in the memory of the remote control.The LED (red) of indoor unit representing HOME LEAVE lights up. (It goes out when theoperation is stopped.)3. End of FunctionThe function ends when the [HOME LEAVE] button is pressed again during HOME LEAVEoperation or when the [POWERFUL] button is pressed.Others The set temperature and airflow rate are memorized in the remote control. When the remotecontrol is reset due to replacement of battery, it is necessary to set the temperature and airflowrate again for HOME LEAVE operation.Start Stop (R1366)TimeSet temp. Normal operation Normal operation“HOME LEAVE operation”set temp. HOME LEAVE operation(R1367)TimeSet temp.“HOME LEAVE operation”set temp.HOME LEAVE operationNormal operation Normal operationStart Stop