Function of RA Indoor Unit SiBE121135_A93 Function and Control1.15 Inverter POWERFUL OperationOutline In order to exploit the cooling and heating capacity to full extent, operate the air conditioner byincreasing the indoor fan rotating speed and the compressor frequency.Detail When the [POWERFUL] button is pressed, the fan speed and target temperature are convertedto the following states for 20 minutes.A = 40 ~ 90 rpm (depending on the model)Ex: POWERFUL operation in coolingNote: For Floor Standing Type: FVXG SeriesPOWERFUL operation is only available in RADIANT 1 (RADIANT operation with heating), it isnot available in RADIANT 2 (RADIANT operation only).Operation mode Fan speed Target temperatureCOOL H tap + A rpm 18°CDRY Dry rotating speed + A rpm Lowered by 2 ~ 2.5°CHEAT / RADIANT 1 H tap + A rpm 30 ~ 32°CFAN H tap + A rpm —AUTO Same as cooling / heating inPOWERFUL operation The target temperature is keptunchanged.(R13571)Target temp.Fan A rpm18˚CH tapSet tap20 minutesIt should be the lower limit ofcooling temperature.It counts 20 minutes. alsoin the remote controller.POWERFULONPOWERFULOFFEnding condition: "or" in 1 to 31. After the lapse of 20 minutes.2. Operation OFF3. POWERFUL operation is OFF.