Function of RA Indoor Unit SiBE121135_A97 Function and Control1.19 WEEKLY TIMER OperationOutline FTXG, CTXS, FTXS, FVXG, FVXS seriesUp to 4 timer settings can be saved for each day of the week (up to 28 settings in total).The 3 items: “ON/OFF”, “temperature”, and “time” can be set.Detail + The illustrations are for FTXG series as representative. Using in these cases of WEEKLY TIMER[Monday] Make timer settings up to programs 1-4.6:00 8:30 17:30 22:006:00 8:30 17:30 22:0021:0019:0010:008:0025˚C 27˚C25˚C25˚C27˚C27˚C 27˚CON ON OFFOFFON ONOFF OFF[Saturday] No timer settings[Sunday] Make timer settings up to programs 1-4.Example: The same timer settings are made for the week from Monday through Friday while different timer settings aremade for the weekend.[Tuesday]to[Friday]Program 1ONProgram 2OFFProgram 3ONProgram 4OFFProgram 1ONProgram 1ONProgram 2OFFProgram 2OFFProgram 3ONProgram 3OFFProgram 4OFFProgram 4ONUse the copy mode to make settings for Tuesday to Friday, because these settings are the same asthose for Monday.• Up to 4 reservations per day and 28 reservations per week can be set in the WEEKLY TIMER. The effective use of thecopy mode ensures ease of making reservations.• The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperaturechanges. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turnoff the air conditioner automatically if the user forgets to turn it off.