Piranha HS-xx RoHS User ManualTeledyne DALSA 03-032-20013-0369Setting a Lower ThresholdPurpose: Sets the low er threshold limit to report in the end -of-linesequence.Syntax: slt iSyntax Elements: iUpper threshold limit in range from 0 to 4095.N otes: LVAL is not high d u ring the end -of-line statistics.Related Comm and s: els, sutExample: slt 10244.6 Saving and Restoring Settings4.6.1 Saving and Restoring Factory and User SettingsFigure 32: Saving and Restoring OverviewFactorySettingsCurrentSession wus wpc,wfc,rus lpc,rfsUserSettingsFactory SettingsYou can restore the original factory settings, inclu d ing the factory calibrated pixelcoefficient set, at any tim e u sing the com m and rfs.User SettingsThere are tw o m ain sets of u ser settings: Area Mod e u ser settings and TDI Mod e u sersettings. After issu ing the u ser settings save com m and , wus, settings are saved d epend ingon w hich m od e the cam era is operating in w hen the com m and is issu ed . Also, w henoperating in TDI Mod e, analog gain and offset, d igital gain and offset, and backgrou ndsu btract valu es are saved as d istinct valu es for Forw ard and Reverse d irections. In otherw ord s, you can program th e cam era to operate w ith an analog gain valu e of +5d b inForw ard d irection and an analog gain valu e of +3d b in Reverse d irection. Forw ard andReverse d irection settings are saved sim u ltaneou sly w ith the wus com m and . N ote thatw hen you sw itch d irections, th e settings saved for that d irection are au tom atically load ed .All manuals and user guides at all-guides.com