Piranha HS-xx RoHS User ManualTeledyne DALSA 03-032-20013-03774.7.4 Voltage MeasurementThe com m and vv d isplays the cam era’s inpu t voltage. N ote that the voltagem easu rem ent featu re of the cam era provid es only approxim ate resu lts (typically w ithin10%). The m easu rem ent shou ld not be u sed to set the applied voltage to the cam era bu tonly u sed as a test to isolate gross problem s w ith the su pply voltage.4.7.5 Camera Frequency MeasurementPurpose: Returns the frequency for the requested Camera Link controlsignalSyntax: gsf iSyntax Elements: iCamera Link control signal to measure:1: CC1 (EXSYN C)2: CC2 (Spare)3: CC3 (Forw ard )4: CC4 (Spare)Example: gsf 14.7.6 Returning Camera SettingsReturning All Camera Settings with the CameraParameter ScreenThe cam era param eter (gcp) screen retu rns all of the cam era’s cu rrent settings. Figu re 35below d escribes the gcp screen for the Piranha H S-8k cam era.To read all current camera settings, use the command:Syntax: gcpFigure 35: Example GCP Screen for HS-40-04k40 TDI Mode OperationGCP Screen DescriptionC A M E R A S E T T I N G SCamera Model No.: HS-xx-xxxxx-xx-R Camera mod el number.Sensor Serial No.: xxxxxxxxx Sensor serial number.Firmware Design Rev.: xx-xx-xxxxx-xx Firmw are d esign revisionnumber.CCI Version: xx-xxx-xxxxx-xx Camera controlinformation.FPGA Version: xx-xx-xxxx-xx DSP d esign revisionnumber.UART Baud Rate: 9600 Serial communicationconnection speed set w iththe sbr command . Seesection Setting Baud Ratefor d etails.All manuals and user guides at all-guides.com