518.4.8 S200 Base Unit Faults (b-faults)As previously stated the base unit Status LED will flash a code if the drive is in a faultedcondition. The following table explains the fault code.FlashCountStatus Resulting Drive Action Reset Method1 No Fault drive disabled Normal Operation2 Motor Over Temp sensorhas trippedDrive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power3 Drive Over/Under Temp Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power4 Drive I*t Too High;Exceeded RMS ratings ofthe drive.Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power5 Motor I*I*t Too High;Exceeded RMS ratings ofthe motor.Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power6 Reserved7 Bus Over Voltage; Mainshigh-line or excessiveregeneration.Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power8 Bus Under Voltage Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power9 Motor l-l or l-n Short Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power10 Output Over Current Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power11 Hall Fault Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power12 SFD Configuration Error Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power13 SFD Short Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power14 SFD Motor Data Error Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power15 SFD Sensor Failure Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power16 SFD UART Error Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power17 SFD Comm Error Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power18 Option Card Watch DogTime outDrive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power19 PosErr Too Large Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI‘Drive Reset’ Button, or Cycle Power20