1.4 Front ViewMCB 152Safe OptionPROFIsafeSW. ver. xx.xxOption B130B9860LED:11 2 3 4 5 6 7 8 9 10 11 122 3 4Y33/DI1 AGNDGNDGNDGNDDI1 BNCNC24 VS 37DI2 ADI2 B130BE100.10Illustration 1.2 Safety Option MCB 152 Front View.1.5 Hardware and Software RequirementsThe following software versions are required as a minimumfor using Safety Option MCB 152:• LCP software version 7.0.• FC 302 firmware version 7.26.• PROFINET software version 3.00.• MCT 10 Set-up Software version 3.23. A licensekey is required to use the full set of features.1.5.1 CompatibilityThe safety option is compatible with all VLT®AutomationDrive FC 302 frequency converters in thepower range from 0.37 kW-75 kW. Compliance to higherpower ranges is pending. Contact the local supplier forlatest information.1.6 Additional ResourcesThe following documentation on safety option installationand configuration is available:• MCT 10 Set-up Software Operating Instructionsdescribe how to configure the safety option.• VLT® AutomationDrive FC 301/FC 302 OperatingInstructions describe the frequency converter.• VLT® AutomationDrive PROFINET MCA 120 Instal-lation Guide describes how to install thePROFINET option.• VLT® Frequency Converters Safe Torque OffOperating Instructions describe the use ofDanfossVLT® frequency converters in functionalsafety applications.Supplementary publications and manuals are availablefrom Danfoss. See vlt-drives.danfoss.com/Support/Technical-Documentation/ for listings.1.7 Document VersionThis manual is regularly reviewed and updated. Allsuggestions for improvement are welcome. Table 1.1 showsthe document version.Edition RemarksMG37F1xx New documentTable 1.1 Document Version1.8 Compliance and CertificationsThe safety option is certified for use in safety applicationsup to and including• SIL 2 according to EN IEC 61508 and EN IEC62061.• Performance Level PL d.• Category 3 according to EN ISO 13849-1.Safety requirements are based on the standards valid atthe time of certification. The IFA (Institute for OccupationalSafety & Health) has approved the safety option for use insafety-related applications where the de-energised state isconsidered to be the safe state. All of the examples relatedto I/O included in this manual are based on achieving de-energisation as the safe state.ApprovalsSafety Option MCB 152 is tested and certified by PNO.1.9 DisposalDo not dispose of equipment containingelectrical components together withdomestic waste.Collect it separately in accordance withlocal and currently valid legislation.Introduction Operating InstructionsMG37F102 Danfoss A/S © 10/2014 All rights reserved. 51 1