8 Specifications8.1 Electrical Data8.1.1 Mains Supply 1x200–240 V ACType designation P1K1 P1K5 P2K2 P3K0 P3K7 P5K5 P7K5 P15K P22KTypical shaft output [kW] 1.1 1.5 2.2 3.0 3.7 5.5 7.5 15 22Typical shaft output at 240 V [hp] 1.5 2.0 2.9 4.0 4.9 7.5 10 20 30Protection rating IP20/Chassis A3 – – – – – – – –Protection rating IP21/Type 1 – B1 B1 B1 B1 B1 B2 C1 C2Protection rating IP55/Type 12 A5 B1 B1 B1 B1 B1 B2 C1 C2Protection rating IP66/NEMA 4X A5 B1 B1 B1 B1 B1 B2 C1 C2Output currentContinuous (3x200–240 V) [A] 6.6 7.5 10.6 12.5 16.7 24.2 30.8 59.4 88Intermittent (3x200–240 V) [A] 7.3 8.3 11.7 13.8 18.4 26.6 33.4 65.3 96.8Continuous kVA at 208 V [kVA] 2.4 2.7 3.8 4.5 6.0 8.7 11.1 21.4 31.7Maximum input currentContinuous (1x200–240 V) [A] 12.5 15 20.5 24 32 46 59 111 172Intermittent (1x200–240 V) [A] 13.8 16.5 22.6 26.4 35.2 50.6 64.9 122.1 189.2Maximum pre-fuses [A] 20 30 40 40 60 80 100 150 200Additional specificationsMaximum cable cross-section (mains, motor, brake)[mm2 (AWG)] 0.2–4 (4–10) 10 (7) 35 (2) 50 (1/0) 95 (4/0)Maximum cable cross-section for mains withdisconnect switch [mm2 (AWG)]5.26(10) 16 (6) 16 (6) 16 (6) 16 (6) 16 (6) 25 (3) 50 (1/0) 2 x 50 (2x 1/0)9) 10)Maximum cable cross-section for mains withoutdisconnect switch [mm2 (AWG)]5.26(10) 16 (6) 16 (6) 16 (6) 16 (6) 16 (6) 25 (3) 50 (1/0) 95 (4/0)Cable insulation temperature rating [°C (°F)] 75(167)75(167)75(167)75(167)75(167) 75 (167) 75 (167) 75 (167) 75 (167)Estimated power loss3) at rated maximum load [W]4) 44 30 44 60 74 110 150 300 440Efficiency5) 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98Table 8.1 Mains Supply 1x200–240 V AC, Normal Overload 110% for 1 Minute, P1K1–P22KSpecifications Operating GuideMG20MD02 Danfoss A/S © 10/2016 All rights reserved. 498 8