3.22 Parameters: 32-** MCO Basic SettingsParameters in this group are available when VLT® MotionControl Option MCO 305 is installed in the frequencyconverter. For information about the option, see the VLT®Motion Control Option MCO 305 Operating Instructions.3.23 Parameters: 33-** MCO AdvancedSettingsParameters in this group are available when VLT® MotionControl Option MCO 305 is installed in the frequencyconverter. For information about the option, see the VLT®Motion Control Option MCO 305 Operating Instructions.3.24 Parameters: 34-** MCO Data ReadoutsParameters in this group are available when VLT® MotionControl Option MCO 305 is installed in the frequencyconverter. For information about the option, see the VLT®Motion Control Option MCO 305 Operating Instructions.3.25 Parameters: 35-** Sensor Input OptionParameters for configuring the functionality of VLT® SensorInput MCB 114.3.25.1 35-0* Temp. Input Mode (MCB 114)35-00 Term. X48/4 Temperature UnitSelect the unit to be used with temperature input X48/4 settingsand readouts:Option: Function:[60] * °C[160] °F35-01 Term. X48/4 Input TypeView the temperature sensor type detected at input X48/4:Option: Function:[0] * Not Connected[1] PT100 2-wire[3] PT1000 2-wire[5] PT100 3-wire[7] PT1000 3-wire35-02 Term. X48/7 Temperature UnitSelect the unit to be used with temperature input X48/7 settingsand readouts:Option: Function:[60] * °C[160] °F35-03 Term. X48/7 Input TypeView the temperature sensor type detected at input X48/7:Option: Function:[0] * Not Connected[1] PT100 2-wire35-03 Term. X48/7 Input TypeView the temperature sensor type detected at input X48/7:Option: Function:[3] PT1000 2-wire[5] PT100 3-wire[7] PT1000 3-wire35-04 Term. X48/10 Temperature UnitSelect the unit to be used with temperature input X48/10settings and readouts:Option: Function:[60] * °C[160] °F35-05 Term. X48/10 Input TypeView the temperature sensor type detected at input X48/10:Option: Function:[0] * Not Connected[1] PT100 2-wire[3] PT1000 2-wire[5] PT100 3-wire[7] PT1000 3-wire35-06 Temperature Sensor Alarm FunctionSelect the alarm function:Option: Function:[0] Off[2] Stop[5] * Stop and trip[27] Forced stop and trip3.25.2 35-1* Temp. Input X48/4 (MCB 114)35-14 Term. X48/4 Filter Time ConstantRange: Function:0.001 s* [0.001 - 10s]Enter the filter time constant. This is afirst-order digital low-pass filter timeconstant for suppressing electrical noisein terminal X48/4. A high time constantvalue improves dampening but alsoincreases the time delay through thefilter.35-15 Term. X48/4 Temp. MonitorThis parameter facilitates the possibility of enabling or disablingthe temperature monitor for terminal X48/4. Set the temperaturelimits in parameter 35-16 Term. X48/4 Low Temp. Limit andparameter 35-17 Term. X48/4 High Temp. Limit.Option: Function:[0] * Disabled[1] EnabledParameter Descriptions Programming GuideMG33ML02 Danfoss A/S © 02/2016 All rights reserved. 1893 3