2.1.1 LCD DisplayThe display has backlight and a total of 6 alpha-numericlines. The display lines show the direction of rotation(arrow), the selected set-up, and the programming set-up.The display is divided into 3 sections.Top sectionThe top section shows up to 2 measurements in normaloperating status.Middle sectionThe top line shows up to 5 measurements with relatedunit, regardless of status (except in the case of alarm/warning).Bottom sectionThe bottom section always shows the state of thefrequency converter in Status mode.Top sectionMiddle sectionBottom sectionStatus43 RPM1.4 HzAuto Remote Running! Pwr.card temp (W29)2.9%5.44 A 25.3kW1(1)130BP074.10!Illustration 2.2 DisplayThe active set-up (selected as the active set-up inparameter 0-10 Active Set-up) is shown. When programminganother set-up than the active set-up, the number of theprogrammed set-up appears to the right.Display contrast adjustmentPress [Status] and [▲] for darker display.Press [Status] and [▼] for brighter display.Most parameter set-ups can be changed immediately viathe LCP, unless a password has been created viaparameter 0-60 Main Menu Password or viaparameter 0-65 Personal Menu Password.Indicator lightsIf certain threshold values are exceeded, the alarm and/orwarning indicator lights up. A status and alarm text appearon the LCP.The ON indicator light is activated when the frequencyconverter receives mains voltage or via a DC bus terminalor 24 V external supply. At the same time, the backindicator light is on.• Green LED/On: Control section is working.• Yellow LED/Warn: Indicates a warning.• Flashing Red LED/Alarm: Indicates an alarm.OnWarn.Alarm130BP044.10Illustration 2.3 Indicator LightsLCP keysThe control keys are divided into functions. The keys belowthe display and indicator lights are used for parameter set-up, including option of display indication during normaloperation.130BP045.10Status QuickMenuMainMenuAlarmLogIllustration 2.4 LCP Keys[Status]Indicates the status of the frequency converter and/or themotor. Select between 3 different readouts by pressing[Status]: 5 line readouts, 4 line readouts, or smart logiccontrol.Press [Status] for selecting the mode of display or forchanging back to display mode from either the quickmenu mode, the main menu mode, or the alarm mode.Also use [Status] to toggle single or double readout mode.[Quick Menu]Allows quick access to different quick menus such as:• My personal menu.• Quick set-up.• Changes made.• Loggings.Press [Quick Menu] to program the parameters belongingto the Quick Menu. It is possible to switch directlybetween quick menu mode and main menu mode.[Main Menu]Is used for programming all parameters.It is possible to switch directly between main menu modeand quick menu mode.Parameter shortcut can be carried out by pressing down[Main Menu] for 3 s. The parameter shortcut allows directaccess to any parameter.How to Program Programming GuideMG33MP02 Danfoss A/S © 10/2018 All rights reserved. 132 2