36-60 Terminal X49/11 Analogue OutputSelect the functionality of terminal X49/11.Option: Function:[141] Bus ctrl 0-20mA t.o.36-62 Terminal X49/11 Min. ScaleRange: Function:0 %* [0 -200 %]Match the minimum output of terminalX49/11 with a required value. For moreinformation, see parameter 36-42 TerminalX49/7 Min. Scale.36-63 Terminal X49/11 Max. ScaleRange: Function:100 %* [0 -200 %]Scale the maximum output of terminalX49/11. For more information, seeparameter 36-43 Terminal X49/7 Max. Scale.36-64 Terminal X49/11 Bus ControlRange: Function:0 %* [0 - 100 %] This parameter contains the output level ofterminal X49/11 if the terminal is controlledby a fieldbus.36-65 Terminal X49/11 Timeout PresetRange: Function:0 %* [0 - 100 %] The frequency converter sends the value ofthis parameter to the output terminal whenthe terminal is controlled by a fieldbus and atimeout is detected.3.29 Parameters: 40-** Special Settings40-40 Fault Log: Ext. ReferenceRange: Function:0 %* [-200 - 200 %]40-41 Fault Log: FrequencyRange: Function:0 Hz* [0 - 6500 Hz]40-42 Fault Log: CurrentRange: Function:0 A* [0 - 10000 A]40-43 Fault Log: VoltageRange: Function:0 V* [0 - 6000 V]40-44 Fault Log: DC Link VoltageRange: Function:0 V* [0 - 10000 V]40-45 Fault Log: Control WordRange: Function:0* [0 - 65535 ]40-46 Fault Log: Status WordRange: Function:0* [0 - 65535 ]3.29.1 40-5* Advanced Control SettingsParameters for configuring the advanced motor controlsettings.40-50 Flux Sensorless Model ShiftUse this parameter to enable or disable the shifting between fluxmodel 1 and flux model 2 at low speed. See alsoparameter 1-66 Min. Current at Low Speed.Option: Function:[0] Off[1] On40-51 Flux Sensorless Corr. GainRange: Function:Size related* [0.1 - 200.0 ]3.30 Parameters: 42-** Safety FunctionsThe parameters in this parameter group are available whena safety option is installed in the frequency converter. Forinformation about the safety-related parameters, see theoperating instructions for the safety options:• VLT® Safety Option MCB 150/151 OperatingInstructions.• VLT® Safety Option MCB 152 Operating Instructions.42-37 Level 1 Password BufferRange: Function:Size related* [0 - 8 ]42-87 Time Until Manual TestRange: Function:8761 h* [0 - 8761 h]3.31 Parameters: 43-** Unit ReadoutsThe parameters in this group provide readouts formonitoring the operation of frequency converters in theD–F enclosure sizes.3.31.1 43-0* Component StatusThis parameter group contains read-only information onhardware components in the power section. All parametersin this group are arrays:Parameter Descriptions Programming GuideMG33MP02 Danfoss A/S © 10/2018 All rights reserved. 2493 3