3.16 Parameters: 15-** Drive Information3.16.1 15-0* Operating Data15-00 Operating hoursRange: Function:0 h* [0 - 2147483647 h] View how many hours the frequencyconverter has run. The value is savedwhen the frequency converter isturned off.15-01 Running HoursRange: Function:0 h* [0 - 2147483647h]View how many hours the motor hasrun. Reset the counter in 15-07 ResetRunning Hours Counter. The value issaved when the frequency converter isturned off.15-02 kWh CounterRange: Function:0 kWh* [0 -2147483647kWh]Registering the power consumption ofthe motor as a mean value over 1hour. Reset the counter inparameter 15-06 Reset kWh Counter.15-03 Power Up'sRange: Function:0* [0 - 2147483647 ] View the number of times the frequencyconverter has been powered up.15-04 Over Temp'sRange: Function:0* [0 - 65535 ] View the number of frequency convertertemperature faults, which have occurred.15-05 Over Volt'sRange: Function:0* [0 - 65535 ] View the number of frequency converterovervoltages, which have occurred.15-06 Reset kWh CounterOption: Function:[0] * Do not reset No reset of the kWh counter is desired.[1] Reset counter Press [OK] to reset the kWh counter to zero(see parameter 15-02 kWh Counter).NOTICEThe reset is carried out by pressing [OK].15-07 Reset Running Hours CounterOption: Function:[0] * Do notreset15-07 Reset Running Hours CounterOption: Function:[1] ResetcounterSelect [1] Reset and press [OK] to reset therunning hours counter to zero (seeparameter 15-01 Running Hours). Thisparameter cannot be selected via the serialport, RS485.Select [0] Do not reset if no reset of therunning hours counter is desired.3.16.2 15-1* Data Log SettingsThe data log enables continuous logging of up to 4 datasources (15-10 Logging Source) at individual rates(parameter 15-11 Logging Interval). A trigger event(15-12 Trigger Event) and window (15-14 Samples BeforeTrigger) are used to start and stop the loggingconditionally.15-10 Logging SourceArray [4]Option: Function:Select which variablesare to be logged.[0] * None[15] Readout: actual setup[1472] Legacy Alarm Word[1473] Legacy Warning Word[1474] Leg. Ext. Status Word[1600] Control Word[1601] Reference [Unit][1602] Reference %[1603] Status Word[1606] Absolute Position[1610] Power [kW][1611] Power [hp][1612] Motor Voltage[1613] Frequency[1614] Motor current[1616] Torque [Nm][1617] Speed [RPM][1618] Motor Thermal[1620] Motor Angle[1621] Torque [%] High Res.[1622] Torque [%][1624] Calibrated Stator Resistance[1625] Torque [Nm] High[1630] DC Link Voltage[1632] Brake Energy /s[1633] Brake Energy Average[1634] Heatsink Temp.[1635] Inverter Thermal[1648] Speed Ref. After Ramp [RPM][1650] External ReferenceParameter Descriptions VLT® AutomationDrive FC 301/302154 Danfoss A/S © Rev. 10/2014 All rights reserved. MG33MJ0233