PRODUCT DESCRIPTION911.7 TYPICAL LAYOUTSThe following typical layout refers to the system hardware configurations, but it also requiresthe correct setup of the software configuration parameters (see par. 3.2 for details).Other layouts require the use of DS6300 scanner having a specific decoder base.The accessories and cables indicated in the following figures are Datalogic products. Wesuggest their use to guarantee the correct system functioning.1.7.1 Point-to-PointUsing a Point-to-Point layout, the data is transmitted on the Main interface as well as on theAuxiliary interface. The Main interface can be selected for RS232 or RS485 full-duplexcommunications.Two different layouts are available according to the DS6300 reader model used for theconnection.Master/Slave ModelsWhen On-Line operating mode is used, the reader is activated by an External Trigger(photoelectric sensor) when the object enters its reading zone. In the following case, thesignal is passed to the DS6300 by the C-BOX 100, which also supplies the system.Figure 11 – Point-to-Point for Master/Slave ModelsFieldbus ModelsIn this case no External Trigger is used and the C-BOX 100 only supplies the reader. TheDS6300 (Ethernet, DeviceNet or Profibus model) is connected to a fieldbus remote Host. Itcan be activated by a signal generated by the remote Host or be always active if working inAutomatic operating mode.Figure 12 – Point-to-Point for Fieldbus ModelsM/SPresenceSensorC-BOX 100PG6000Local HostCAB600XRemote HostFieldbusC-BOX 100PG6000CAB601X