SOFTWARE CONFIGURATION3733.4 PARAMETER DEFAULT VALUESThe following table contains the list of the factory default settings for the DS6300.Genius™ also allows checking the parameter default values by selecting the "Compareparameters" option available in the Tools menu and comparing the current scannerconfiguration to the default one.Parameter Default SettingCode DefinitionMulti Label Disabled (unchecked)No read Message Global No Read MessageNo Read String Multiple Read Message Disabled (unchecked)Code Label Settings #1Code Symbology Interleaved 2 of 5Label Length 8Check Digit Disabled (unchecked)Decoding Severity 3Code Label Settings #2Code Symbology Code 39Label Length VariableCheck Digit Disabled (unchecked)Decoding Severity 3Operating ModesOperating Mode Selection On LineOn Line Options On Line 1 InputStart Input Number 1Start Input Active Level Active ClosedReading Phase Timeout DisabledDevice Assignment AloneReading ParametersBeam Shutter DisabledOverflow Ratio 7Reading Mode ReconstructionMax Scan Gap 5Max Stacked Codes 1Data FormatApplication Protocol Type StandardHeader TX Start With dataHeader String Termination After No Read Message EnabledTermination String Data Packet Separators Message Tx Trigger Selection On Decoding