DRAGON™ D131/M1311565.5.2 Enter Sleep TimeoutFor readers that have the Sleep state enabled, this timeout determines when thereader will enter this state.5.6 READING PARAMETERS5.6.1 Trigger SignalThis mode determines how the reading phase is controlled when the hardwaretrigger operating mode is selected:• trigger active level: the reader goes ON when the trigger is pressed and goesOFF when it is released• trigger active pulse: the reader goes ON at the first trigger press and goes OFFonly at a second press5.6.2 Trigger ClickWhen enabled, it activates a "click" sound upon each trigger pressure.5.6.3 Trigger-Off TimeoutWhen this timeout is selected, the reader turns OFF automatically after the desiredperiod of time.5.6.4 Reads per CycleIn general, a reading cycle corresponds to the ON + OFF times of a device.The resulting effects of this parameter on code reading depend on other relatedconfiguration conditions. Here are the definitions of ON and OFF times.• For readers using the software trigger parameter (FLASH MODE), a readingcycle corresponds to the flash on + flash off times. Code reading takes placeduring the flash on time.• For readers using the hardware trigger parameter, a reading cycle correspondsto a trigger press (ON) + one of the following OFF events:trigger release (for trigger active level)a second trigger press (for trigger active pulse)trigger-off timeout (see par. 5.6.3).