GRYPHON™1585.12 DEFAULT PARAMETERS FOR POS TERMINALSThe default values of the RS232 and Data Format parameters for POS terminals arelisted in the following table:NIXDORF Mode A FUJITSU ICL ModeRS232 GroupBaud Rate 9600 9600 9600Parity Odd None EvenData Bits 8 8 8Stop Bits 1 1 1Handshaking Hardware (RTS/CTS) None RTS always ONACK/NACK Protocol Disabled Disabled DisabledFIFO Disabled Enabled EnabledInter-Character Delay Disabled Disabled DisabledRX Timeout 9.9 sec 2 sec 9.9 secSerial Trigger Lock Disabled Disabled DisabledData Format GroupCode Identifier Custom Custom CustomHeader No Header No Header No HeaderTerminator CR CR CRField Adjustment Disabled Disabled DisabledCode Length TX Not Transmitted Not Transmitted Not TransmittedCharacter Replacement Disabled Disabled DisabledAddress Stamping Disabled Disabled DisabledAddress Delimiter Disabled Disabled DisabledThe table below lists all the Code Identifiers available for the POS terminals:CODE NIXDORF Mode A FUJITSU ICL ModeUPC-A A0 A AUPC-E C0 E EEAN-8 B FF FFEAN-13 A F FCode 39 M None C [code length]Codabar N None N [code length]Code 128 K None L [code length]Interleaved 2 of 5 I None I [code length]Code 93 L None NoneIndustrial 2 of 5 H None H [code length]UCC/EAN 128 P None L [code length]MSI/Plessey O None NoneRSS E None NonePDF417 Q None NoneOther None None None