Remote Scale Display Placement/InstallationProduct Reference Guide 2-29Placing and Installing the Remote Scale Display(Short Pedestal Base ONLY)1. Determine where you want to install the Remote Scale Displaybased on your counter design, the viewing angle and lighting con-siderations discussed previously. Reference Figure 2-14 for the dis-play’s physical dimensions.2. Use the short pedestal base template provided in Figure 2-16 tomark locations of the mounting screw and cable routing holes. Themounting screw holes are on 3 3/8” (8.57 cm) centers.3. The cable can either be routed through a 3/4” (19 mm) diameterhole directly under the mounting base or through the cutout in theback of the base (see Figure 2-15).4. Drill the mounting screw holes using a drill bit of the appropriatediameter for your mounting screws or bolts.5. Drill the cable routing hole using a 3 /4” (19 mm) drill bit(optional).It may be necessary to shorten the stalk that supports the display head sothat the display is installed at eye level.NOTEThe connector at the Remote Scale Display end is secured with a rubber bandduring shipping to prevent damage to the “locking tabs” (see Figure 2-15).After routing the cable, remove this rubber band before the cable end con-necting to the Remote Scale Display head. Failure to remove the band willkeep the connector from latching properly when it is connected to RemoteScale Display port.NOTEBefore drilling, ensure the holes in your base match with the holes indicatedon the template.