MATRIX 300™ REFERENCE MANUAL6444.6 OUTPUTSCAUTION: When Outputs 1 and 2 are connected through the CBXconnection box, they become opto-isolated and polarity sensitive and acquirethe electrical characteristics listed below. To function correctly, they requiresetting the Output Type configuration parameters to NPN for the respectiveoutput in.Three general purpose outputs are available and their meaning can be defined by the user.They are typically used either to signal the data collection result or to control an externallighting system.CBX100/500 Function+V Power Source - OutputsO1+ Output 1 + opto-isolated and polarity sensitiveO1- Output 1 - opto-isolated and polarity sensitiveO2+ Output 2 + opto-isolated and polarity sensitiveO2- Output 2 - opto-isolated and polarity sensitiveO3A Output 3 non opto-isolated (only available on CBX500)-V Power Reference OutputsThe electrical features of the outputs are the following:Outputs 1 and 2 Output 3VCE = 30 Vdc max. Reverse-Polarity and Short-Circuit ProtectedICE = 40 mA continuous max.; 130 mA pulsed max. VOUT (ILOAD = 0 mA) max = 30 VdcVCE saturation = 1 Vdc max. @ 10 mA VOUT (ILOAD = 100 mA) max = 3 VdcPD = 90 mW Max. @ 50 °C ambient temp. ILOAD max = 100 mABy default, Output 1 is associated with the Partial Read and No Read events, which activateswhen the code(s) signaled by the external trigger are not decoded, and Output 2 isassociated with the Complete Read event, which activates when all the selected codes arecorrectly decoded.The output signals are fully programmable being determined by the configuredActivation/Deactivation events, Deactivation Timeout or a combination of the two. Refer tothe Digital I/O folder in the VisiSet™ Help On Line for further details.