REFERENCES1815.9.4 Transmission ModeThis parameter determines whether the reader receives responses or messages fromthe Host or not. In One-Way tx mode, neither Host nor cradle responds to the reader.In Two-Way tx mode, the reader mustThe cradle responds (empty message) to the reader, only after good transmission tothe Host, for the following conditions: ACK/NACK enabled, see par.receive a response from either the cradle orthe Host.5.1.2; WEDGE orPEN interface. For these conditions, it is suggested to prolong the Radio ProtocolTimeout, see par. 5.9.1.Enabling Two-Way tx mode temporarily disables FIFO buffering see par. 5.1.3.With ACK/NACK disabled, the Host responds to the reader (through the cradle) withan answer message (message to reader display or command to reader), see par. 6.3and the following figure.BC-80X0 HostdatacablePowerScan®M8300dataTransmission Mode = Two-WaysHost answer messageHost answermessage5.9.5 Beeper Control for Radio ResponseFor M8300 series readers, the data entry good read tone normally results in twobeeps; the first indicates that the reader has decoded the code; the second indicateswhether BC-80X0 has received the data.This can be changed according to the following selections:♦ Normal: both good decode and good receptions are signaled (two beeps).♦ Only Good Decode: only the first beep indicating a good read is signaled.♦ Only Good Reception: only the second beep indicating a good reception issignaled.♦ Off: Neither good read nor good reception beeps are signaled.For all configurations, any transmission errors will always be signaled.