BigIron RX Installation Guide 18353-1001811-01Upgrading the BigIron RX Series software 7Rebooting the management moduleAfter upgrading one or more software images on the management or interface modules, you mustreboot the management module. After the management module reboots, it in turn reboots theinterface modules.To reboot the management module, enter one of the following commands:• reload (this command boots from the default boot source, which is the primary code flash)• boot system flash primary | secondaryDuring the management module reboot, the following synchronization events occur:• If you have a standby management module, the active management module compares thestandby module’s monitor, primary, and secondary images to its own. If you have updatedthese images on the active module, the active module automatically synchronizes the standbymodule’s images with its own.• If you copied the primary or secondary IronWare image to all interface modules using the copycommand with the all keyword, the management module made a copy of the image and storedit in its code flash under the names lp-primary-0 or lp-secondary-0. By default, the BigIron RXSeries system checks the interface modules’ IronWare images, which reside in the code flashof the interface modules and the management module to make sure they are the same in bothlocations. (These IronWare images are stored on the management module only and are not runby the management or interface modules.) If the IronWare images on the interface andmanagement modules are different, the system prompts you to do the following:• If you want to update the IronWare images in the interface module’s code flash with theimages in the management module’s code flash, enter the lp cont-boot sync command at the Privileged EXEC prompt.• If you want to retain the IronWare images in the interface module’s code flash, enter the lpcont-boot no-sync command at the Privileged EXEC prompt.After the management module finishes booting, do the following:• Enter the show module command at any CLI level, and verify that the status of all interfacemodules is CARD_STATE_UP.• Enter the show version command at any CLI level, and verify that all management andinterface modules are running the new software image version.If you find that an interface module is in a waiting state or is running an older software image, thenyou may have forgotten to enter the lp cont-boot sync command at the PrivilegedEXEC prompt.Upgrading the MBRIDGE FPGA on the management moduleBigIron RX Series management modules contain an upgradable FPGA image called MBRIDGE.The MBRIDGE image installed must be compatible with the software version you are running on theBigIron RX Series. Refer to the Software Release Notes for compatibility information.NOTEYou will not need to upgrade the MBRIDGE FPGA image with every Multi-Service software upgrade.Only upgrade this image if specified in the release notes.