28 About Your SystemE1A15 SAS Cable D SAS cable D is missing orbad.Reseat the cable. If theproblem persists, replacecable.If the problem persists,see "Getting Help" onpage 205.E1A18 PDB CtrlCableControl cable for the powerdistribution board (PDB) ismissing or bad.Reseat the cable. If theproblem persists, replacecable.If the problem persists,see "Getting Help" onpage 205.E1A19 12V CableFaultPower cable for the PDB orcabled power supply ismissing or bad. They systemwill not turn on.Reseat the cable. If theproblem persists, replacecable.If the problem persists,see "Getting Help" onpage 205.E1B01 USB#OvercurrentDevice plugged in thespecified USB port causedan overcurrent condition.Reseat the device cable. Ifthe problem persists,replace or remove thedevice.E2010 No Memory No memory is installed inthe system.Install memory (see"Installing MemoryModules" on page 130).E2011 Mem ConfigErrMemory detected, but is notconfigurable. Error detectedduring memoryconfiguration.See "TroubleshootingSystem Memory" onpage 174.E2012 UnusableMemoryMemory is configured, butnot usable. Memorysubsystem failure.See "TroubleshootingSystem Memory" onpage 174.Table 1-5. LCD Status Messages (continued)Code Text Causes Corrective Actions