58 PowerEdge FX2 – FN I/O Module – VLT Deployment Guide | Version 2.2interface range te0/11-12description “Link to DellS4810”no switchportport-channel-protocol lacpport-channel 121 modeactiveexitno shutdownexitinterface rangete0/11-12description “Link toDell S4810”no switchportport-channel-protocol lacpport-channel 121mode activeexitno shutdownexitConnection to Server NICs and Connections to S4810 Switches8.2 Environment Three: Configuring the Dell Networking S4810In this section, the S4810 switches are configured (Figure 43). The configuration steps outlined beloware repeated on both IOMs. When validating the configurations in this guide the following managementIP addresses (Table 10) were used.Management IP addressesHostname IP Address SubnetS4810-1 172.25.190.37 255.255.0.0S4810-2 172.25.190.38 255.255.0.0The VLT active/active capabilities of the S4810 and the IOM are the same. Therefore, theconfigurations should look and behave in the same manner.