Dell39PowerEdge R210 II Technical Guide5 ASSR0CBL Add-in SAS/SATA RAID card, RAID 0 (PERC S300) 3 46 ASSR1CBL Add-in SAS/SATA RAID 1 (PERC S300) 2 27 ASSR5CBL Add-in SAS/SATA RAID card, RAID 5 (PERC S300) 3 48 ASSR10CBL Add-in SAS/SATA RAID card, RAID 10 (PERC S300) 4 49 ASSCBL Add-in SAS/SATA RAID card, No RAID(PERC H200)1 410 ASSR0CBL Add-in SAS/SATA RAID card, RAID 0 (PERC H200) 2 411 ASSR1CBL Add-in SAS/SATA RAID card, RAID 1 (PERC H200) 2 2SAS/SSDRAID12 ASSR10CBL Add-in SAS/SSD RAID card, RAID 10(PERC H200)4 4Note: Configurations that require more than 3 hard drives will be available in Q2 2011.Additional restrictions for RAID configurations are listed as follows: Hard drives must be all 3.5‖ or 2.5‖ (2.5‖ drives available Q2 2011) Must be all SAS or all SATA or all SSD No Mixed Hard drives allowed SSD support requires PERC H200 PERC S300 does not support SSDThe PERC S300 does not support the following virtualization solutions: Microsoft® Hyper-V™ server 2008 x64 (download version) Microsoft Windows Server® 2008 x64 (Hyper-V™ role enabled) Microsoft Windows Server 2008 SP2 x64 (Hyper-V™ role enabled) Microsoft Windows Server 2008 R2 (Microsoft Windows® 7 includes SP2 bits) x64 (Hyper-Vrole enabled)The PERC S300 does not support Linux® operating systems or VMware® virtualization software.12.4 Optical DrivesThe R210 II supports one SATA interface DVD-ROM or DVD+/-RW.12.5 Tape DrivesExternal tape drives and tape libraries are supported. No internal tape drive support is available.For more information on supported tape drives and tape libraries, see Dell.com/Storage.