Indicator DescriptionBlinking Amber The indicator blinks for 15 seconds after the slot identify command.Off The storage controller slot is operating normally.Power indicator onstorage controllercardRegular BlinkingGreenThe storage controller card is operating normally.Irregular BlinkingGreenThe storage controller card is in a fault condition.Off The storage controller card is not receiving power.Removing An Integrated Storage Controller CardCAUTION: Many repairs may only be done by a certified service technician. You should only performtroubleshooting and simple repairs as authorized in your product documentation, or as directed by the online ortelephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by yourwarranty. Read and follow the safety instructions that came with the product.1. If installed, remove the front bezel.2. Turn off the server modules using the operating system commands or the CMC.3. Turn off the enclosure, including any attached peripherals, and disconnect the enclosure from the electrical outletand peripherals.4. To reduce the chassis weight, remove the following (if required):a) hard drivesb) server modulesc) power supplies5. If applicable, rotate the system feet inward and lay the system on its side on a flat stable surface, with the coverrelease latch side on top.6. Open the system.7. Push down the two release levers at the edge of the card to disengage the card from the connector.8. Orient the card so that the other end of the card disengages from the storage-controller card holder on the systemboard.86