Parameter SpecificationsStorage Humidity 5 to 95 percent, non-condensingThermal Output Typical: 1170.4 BTU/hr (343 W)Maximum: 3057.3 BTU/hr (896 W)Maximum operational altitude 10,000 feet (3,048 meters)Maximum non-operational altitude No performance degradation to 35,000 feet (10,668 meters)Shock SV0115 — ODMTable 12. AC power requirementsParameter SpecificationsPower Supply 100–240 VAC 50/60 HzMaximum Current Draw Per System 12A–6.5A @ 100–240 VACPSU Maximum Power Capability 1100 WattsTypical and Maximum Power Consumption 343 Watts typical896 Watts maximumReliability MTBF 1,154,397 hoursTable 13. DC power requirementsParameter SpecificationsPSU Maximum Power Capability 1100 WattsPSU Maximum current required 32AMinimum and maximum input voltage range −40.5 V / −48 V/ −60 VInput power at full load −40.5 V/970 W −48 V/930 W −60 V/950 W, without fan−40.5 V/980 W −48 V/940 W −60V/ 960 W, with fanInput current at full load −40.5V/23.8A −48V/19.0A −60V/ 15.6A, without fan−40.5V/24.0A −48V/19.2A −60V/ 16.0A, with fanStart up VDC 39.0+/−1.5 VStart off VDC 37.5+/−1.5 VIEEE standardsThe S6100–ON complies with the following IEEE standards:• 802.3ab Gigabit Ethernet (1000BASE-T)• 802.3ae 10 Gigabit Ethernet (10GBASE-X)• 802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports• 802.3ba 100 Gigabit Ethernet• 802.3bj 100 Gigabit Ethernet50 Specifications