ASDA Series Application Note Introduction of PR OperationMarch, 2015 1-51.1.2 Mapping ParameterAdvantages about using mapping parameters are listed below:1. Quickly read and write: It allows users to consecutively read and write communicationaddresses of different parameter groups that are not jointed.2. Read any parameters from PC scope: PC scope channel can read mapping parameters; it canread any parameters via mapping parameters.3. Enable the function of reading parameter value after password is set: users may access theparameter that is going to be monitored via mapping parameter. Then, users may still read itsvalue via mapping parameter when a parameter is set with password.ASDA-A2 can map any of the parameters to the specified address. In ASDA-A2 system, 8groups of mapping parameters are available: P0-35 ~ P0-42 is the index group, the parametervalue specified by the index group will be mapped to P0-25 ~ P0-32 respectively. See Figure 1.5,the input value of P0-35 ~ P0-42 is in hexadecimal format.P0-42Index ContentP0-32P0-41P0-40P0-39P0-38P0-37P0-36P0-35P0-31P0-30P0-29P0-28P0-27P0-26P0-25Figure 1.5 Mapping ParametersBesides parameter setting, mapping parameter can also be set via Status Monitor in ASDA-Soft,which shown in Figure 1.6.8 groups of mapping parameter are organized together in Status Monitor. Steps to setup areshown below:1. Select the mapping parameter that is going to be used.2. Use the drop-down list to select the parameter to be mapped.3. If “32-bit” is selected, the high-word item will be blocked to insure the doubleword is mappedcorrectly, and all bits of the mapping parameters are used to display in the same parameter.