Delta DVP02TK-S Manual
Also see for DVP02TK-S: Manual
D VP02 TK-S/D VP02 TU- S Temper ature C on tr ol Mod ule Man ua l2 - 2 8_22.7 Programmable SV Control ModeThe temperature setting value is not fixed but a setting curve defined by users according to their requirements. By way ofPID control, the temperature input rises along with the defined temperature curve. The device provides 8 patterns andeach pattern with 8 steps, a linking parameter, a loop parameter, and a number of execution steps respectively. Each stephas 2 parameters (temperature setting value and time). After setting these parameters up, each temperature controller willhave its own set of initial pattern and step for creating its own temperature setting curve. Some of the terms are explainedas follows:1. Initial pattern: set the program to start running at a sequential number of patterns.2. Initial Step: set the program to start running at a sequential number of steps.3. Running time: set the temperature duration time, if not necessary, it can be set to 0.4. Step: includes 2 parameter settings: a setting point X and a Running time T, indicating the setting value (SV) to rise toX degree after the time T. If the setting point X is identical to the previous setting, this process is called a Soak,otherwise a Ramp; therefore this control procedure is also called a Ramp Soak control. The first running procedure ispreset as a Soak control, to set the temperature control to setting point X degree in advanced and keep thetemperature at X degree, at a duration time of T.5. Number of loops: Extra loops to be carried out for the pattern. If set to 1, the pattern will be carried out 2 times.6. Executing step: Number of steps executed for each pattern.7. Execution: Before execution, users need to set up all the parameters. If the setting control is in the running mode, theprogram will start running from the initial pattern and initial step, carrying out commands one by one by their setorders. When the setting control is in the ending mode, the SV will stop at the final setting. When the setting control isin the stop mode and the temperature will be at the value before the stop, by re-selecting to run, the program will startrunning from the initial pattern and initial step. When the setting control is in the pause mode and the temperature is atthe value before the pause, by re-selecting to run, the program will start running from the step where the program waspaused, carrying out the remaining parts. During execution, the SV cannot be set up.2.8 ERROR LED IndicatorWhen the analog input channel out of range is detected, the error code will show up and the error LED will also blinking tonotify. Users can disable this functionality to inactivate the error LED blinking, but the error code will still show up.Page CR Description Setting ValueBasic Setup Page 38 Output out of range K0=LED blinking (default)K1=LED not blinking |
Related manuals for Delta DVP02TK-S
manualsdatabase
Your AI-powered manual search engine