Delta X. User Manual65Viewing signals and alarmsThe Stop / View Log mode gives information about the detected signals to the operator. The task of theoperator is to study the dangerous signals, alarms and to go to the Signal Analyzer for locating or savingthe signal to the Known Signals table.The Signals table shows the list of detected signals. All the standard operations with the signals areavailable in this mode: filtering, sorting, etc.The Danger field represents the maximum danger level of the signals (light red) measured during thelast detection. Use the Dangerous filter and the Danger top button to quickly select the most dangeroussignals.When the mode of the Detector is Wide-Range, the Danger level bargraph shows the maximum alarmfrom all the signals, while the Alarms graph shows the distribution of alarms in time.When the mode of the Detector is Signal, the Danger level bargraph represents the maximum alarmfrom the selected signal, while the Alarms graph shows the distribution of alarms in time for the signal.There are two ways of reviewing the logged information:1) Inspection of dangerous signals in the Signals table one by one, and reviewing the alarms ofeach signal on the Alarms graph with the Detector in the Signal mode: Set the signal's filtering as Dangerous Set the Detector's mode as Signal Click, or double-click, the signal in the Signals table. The Alarms graph will show the alarmevents created by the signal Click the events on the Alarms graph. The Waterfall and Spectrogram will show thecorresponding time, while the dBm and Danger columns in the Signals table will reflect thelevels which existed at the time of clicking A click on the Waterfall will display the corresponding measurement in the "Live trace" onthe Spectrogram