Delta X. User Manual7SpecificationGeneral2000/6 Real-Time 100/12 100/4Update rate 2000-3000MHz/sec100 MHz/sec 100 MHz/secFrequency range 40 kHz - 6000MHz100 kHz –12400 MHz40 kHz –4400 MHzReaction time(How quickly a dangerous signal is detected)2-3 sec 60-120seconds45 secondsSpectrum resolution 9 kHz 15 kHz 15 kHzOccupied disk space per 24 hours 12 Gb 1 Gb 0.5 GbTemperature Range 0°C to +65°C 0°C to +50°C 0°C to +70°CDemands on computer 3rd gen. or newerIntel dual/quadCore i-series1 x USB 3.02 x USB 2.0Windows 7, 8 , 1013-14” screenrecommendedIntel® Atom™ N2600 or Intel®Core™ i32 x USB 2.0Windows 7, 8, 1013-14” screen recommendedDisplayed dynamic range -90…-10 dBmDisplayed spectrum spans 0.5, 1, 2, 5, 10, 25, 50, 100, 200, 500, 1000, 2000,3000, 6000 MHzSpectrum graphs Spectrogram, WaterfallSpectrogram's displayed data Persistence, Live, Max, ThresholdDetector's modes Wide-Range, Signal, SelectionFields of "Signals" table Frequency, Bandwidth, Name, dbm Level, dbmPeak Level, Danger Level, Peak Danger LevelFields of "Bands" table Begin, End, Name, Type, Threshold, Priority,Tracker detectionFields of "Known Signals" table Frequency, BW, Name, ModulationODA-4 omnidirectional antenna Can be used with any RF equipment, including receivers, spectrum analyzers, RF detectors, etc. Is capable of receiving the entire frequency range 40 kHz – 6000 MHz with increased sensitivityin the range of 80 MHz - 4000 MHz Tripod mountable (tripod supplied) The tripod can convert to a hand-held unit for manual probing (locating procedure) Connector type: BNC 80 cm cable Dimensions (without tripod) 20 x 3.5 x 0.6 cm Mode of use: receive Indoor use onlyMWA-6 microwave antenna