21SERVICE MODEHow to inputPlug AC cord into power outlet while pressing both the button A and the button B at the same time.No. Mode Button A Button B1 Version display mode 2 8 / ā2 VFD checking mode 5 Power operation (X)3 Cold start mode (initialization) SOURCE 8 / ā4 CD test mode SOURCE Power operation (X)5 CD heat run mode 2 + / 96 Accumulated laser on time display mode 2 Power operation (X)7 Displaying the protection history mode SOURCE + / 91. Version display mode(1) Plug AC cord into power outlet while pressing "2" and "8 / ā" button same time on Main Unit.(2) Press the "SDB/TONE" button to the display the 2nd item information on the Display.ćMain Ī¼-com Ver.ćāćUSB Ī¼-com Ver.ćāćMain Ī¼-com Ver.ćāć»ć»ć»ćMain Ī¼-com Ver.ćV e r 1 2 0 6 0 8 0 2 v E 2ćUSB Ī¼-com Ver.ćU S B V E R2 0 1 2 0 5 2 4 0 1(3) Unplug AC cord to clear this mode.2. VFD checking mode(1) Plug AC cord into power outlet while pressing "Power operation (X)" and "5" button same time on Main Unit.(2) All segment of VFD is turning on and off every one second. MUTING ONļ¼(3) Unplug AC cord to clear this mode.