1425.4 Communicating with the HostComputer5.4.1 Setting the Transmission Speed of the CU-7000Set the transmission speed of the CU-7000 to the same value as that of the BHT and thehost computer, by using the DIP switch provided on the bottom of the CU-7000.(1) Turn the CU-7000 upside down.(2) Remove the protection sheet of the DIP switch from the CU-7000.(3) Set the selectors of the DIP switch as shown below.For 115,200 bps For 57,600 bpsONOFF1 2 3OFFONOFF1 2 3OFFFor 38,400 bps For 19,200 bpsONOFF1 2 3OFFONOFF1 2 3OFFFor 9,600 bps(4) Reinstall the protection sheet.Do not set the DIP switch to any configurations other than one of the five shownabove.5.4.2 Interface Cable Connection(1) Unplug the AC adapter of the CU-7000 from the wall socket.(2) Make sure that the host computer is turned off.(3) Connect the 25-pin plug (Dsub-25P) of the interface cable to the RS-232C interfaceport of the CU-7000.Bottom ViewRS-232C interfacecable(4) Connect the other end of the interface cable to the RS-232C port of the hostcomputer.ONOFF1 2 3OFFDIP switch (whenthe protectionsheet is removed)OFF2 31