25 CE60-3GSM - Installer9.6. Learning Radio Zones9.7. Programming ZoneProgramming the type of insertion and activation of each zone:9.8. Programming ALERT9.9. Exit Time (seconds)9.10. Entry Time (seconds)9.11. Pre-alarm time in SecondsLearning XRadio Zone 01 PProg. Zone RRadio Zone 01 PAt each press, it will move to the next zone (WiredZones and Radio Zones)Short press changes the status:R = sensor with Entry TimeI = Instantaneous alarm sensorD = sensor DisabledLong press changes insertion:T = TotalP = PartialE = ExternalProg. Zone IRadio Zone 01 PProg. Alert DRadio Zone 01 PTime for exit in secondsPress 1 time to start count from zero.Press again to stop the count at the desired value.Exit Time (sec)10Time for entry in secondsPress 1 time to start count from zero.Press again to stop the count at the desired value.Entry Time (sec)10Time of PreAlarm in secondsPress 1 time to start count from zero.Press again to stop the count at the desired value.PreAlarm (sec)00Programming ALERT warning sound(See USERS MANUAL)Learning SensorsSee “LEARNING WIRELESS ZONES” sectionXXXXO