5 CE60-3GSM - Installer1. TECHNICAL FEATURESRADIO ZONES 60 wireless zones with LCD indicationWIRED ZONES 3 wired inputs NC *TAMPER 1 tamper wired input (24 h/24) **AREAS 2 + 1 areas with ALERT functionsRADIO CODE 48 bitsWORKING FREQUENCY 433,92 MHz (with anti-jamming)RANGE 100 m (open field)ARMING Remote control, keypad and transponder key (max 16 devices),mechanical key, SMS, vocal menuEVENT LOG 100 alarm events log with identification of the detector,arming/disarming and SMS sendingSIGNALLING Internal high-power magnetodinamic siren, ALERT function, warningtonesWIRED OUTPUTS TO CONTROL EXTERNALDEVICES1 Relay1 Output +12 V (drop down in alarm)1 Output +12 V (raise up in alarm)OUTPUTS TO POWER EXTERNAL DEVICES 1 Output +12 V for sirens/phone diallers1 programmable Relay AUXALARM DURATION Selectable from 10 to 180 secondsMAXIMUM NUMBER OF ALARMS MAX 4 alarms per detector during arming period(MAX 10 total alarms)DELAYS Programmable Entry and Exit TimesCONTROL PANEL POWER SUPPLY 230 V / 50 Hz / MAX: 80 mA in stand-by, 160 mA in alarmOPERATING TEMPERATURE -15 °C ÷ +45 °CBACKUP BATTERY 12 V MAX 7AhGSM DIALLER• 8 programmable numbers• SMS messages: alarm, panic and telealarm, power supply status,arming status, supervision• Voice calls: alarm, panic, telealarm• Voice MenuTEMPERATURE SENSOR(optional) Thermostat function sensor for relay AUX output management* Refere to +VS. If not in used close always on +VS.** Refere to +VS.IMPORTANT WARNING – CompatibilityCE 60-3 GSM works correctly only with “100” series peripherals.OPTIONAL ACCESSORY – Temperature sensorThis control panel can be equipped with a temperature probe that is connected to CN14connector. Relay AUX, programmed as “Temperature”, will manage the thermoregulation system.