47Machine train (3)Measure using EasyTurn™It is possible to measure with as little as 40º spread between the measurement points.However, for an even more accurate result, try to spread the points as much as possi-ble. The colours indicates where the optimum positions to measure are.1. Adjust laser to the centre of the targets. If needed, adjust the units on the rods,then use laser adjustments knobs.2. Press to register first position. The first position is automatically set to zero.A red marking is displayed.3. Turn shafts outside of the red 20º marking.4. Press to register second position.5. Turn shafts outside of the red markings.6. Press to register third position. The Result and adjust view displayed.7. The result is displayed. You can show the result as graph, table or machine view.See chapter Result.8. From the result view, select to measure next coupling. If you want to adjustthe coupling, select the machine you want to adjust and press . See chapterAdjust.Function buttonsBack. Measure previous position or back to Distance view.See “Control panel” on page 14.Switch to the EasyTurn™ method.Switch to the 9-12-3 method.See “SOFTFOOT” on page 57.Red 20º markingGreen indicates bestmeasurement positionEdge warningS-unitDetector valuesEdge warningWhen the laser beam isclose to the edge, the edgeis “lit up” as a warning. Itis not possible to registervalues when you see theedge warning.www. .com information@itm.com1.800.561.8187