Eaton All-Pro MS245RW Instruction Manual
Questions?/Des questions?/¿Preguntas? 1-800-334-6871 ConsumerProducts@eaton.com1PACKAGING CONTENTS/ C O N T E N U D E L ’ E MBALLAGE/ C O N T E N I D O D E L P A Q U E T EInstruction Manual/Instruccionesin wet locations.• Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.• Fixture should be installed by persons with experience in household wiring or by aqualified electrician. The electrical system, and the method of electrically connectingthe fixture to it, must be in accordance with the National Electrical Code and localbuilding codes.• Do not allow sensor head to touch light housing – maintain at least1 in. space between fixture and sensor.• Keep away from flammable objects. Do not position fixture within 2 in.of any combustible materials.• MINIMUM 90°C SUPPLY CONDUCTORS.• For proper operation and protection against damage, the motion sensor headadjustment knobs must be facing the ground.• This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may causeundesired operation. Under Part 15 of the FCC Rules, any changes or modifications tothe motion detector described in this instruction sheet that are not expressly approvedby Eaton could void the user’s authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If thisequipment does cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user is encouraged totry to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected.- Consult the dealer or an experienced radio/TV technician for help.WARNING: FCC Regulations state that any unauthorized changes ormodifications to this equipment not expressly approved by the manufacturercould void the user’s authorization to operate this equipment.SAVE THESE INSTRUCTIONS.FOR BEST RESULTS• Install the motion sensor/transmitter 8-12 feetabove the ground. (Motion sensor is less sensitiveabove 12 feet.)• Locate motion sensor so motion moves acrossdetection zone (Fig. 1).• Locate sensor away from heat producing sources toITEMS REQUIRED(Purchase separately)• Phillips screwdriver• Outdoor weatherproof silicone caulking• (2) 100 watt (MAX) PAR 38 floodlight bulbsNOTE: This fixture was designed to work with up to 150 watt maximum PAR halogen floodbulbs. For improved energy efficiency, lower wattage PAR halogen flood bulbs may be used.Compact Fluorescent (CFL) bulbs contain electronics which may interfere with the motionsensing function of your fixture and are not recommended. To meet ENERGY STAR ®requirements, maximum lamp wattage can not exceed 250 watts.HOW IT WORKSYour motion activated floodlight senses heat images fromobjects such as people, large animals and automobile engines.When motion is detected, the lights will automatically turnon. Once motion has stopped, the lights will turn off after apreselected time delay. Your motion activated floodlight mayalso be used as a standard floodlight.IMPORTANT SAFETY INSTRUCTIONSWhen using product, basic precautions should always be followed, including the following:• Heed all warnings, including below warnings AND those included on product.• Save these instructions and warnings.• For outdoor use only.• cULus LISTED for wet location.• Disassembly of your fixture will void the warranty.• Your fixture is prewired and preassembled for easy installation.• Read and follow these instructions.• To reduce the risk of a burn during relamping, disconnect power supply to the unitbefore relamping.• Bulb gets HOT quickly!• Always replace bulb with the same wattage or lower wattage than marked. Installinga bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulbwill void the warranty (maximum 150 watt halogen bulb).CAUTION• Connect fixture to a 120 volt, 60 Hz power source. Any other connection voidsthe warranty.• Mount fixture to a grounded, recessed-mounted standard junction box marked for useMS245R (Bronze)ENGLISHUp to70 feet270 degrees1WARNINGA. Motion detectorand light fixtureDetector de movimientoy accesorioLuminaire avec détecteur demouvementB. (2) Lampholder gaskets(2) Juntas obturadorasdel receptáculo(2) Joints statiques de douilleD. (2) #6 and (2) #8 mounting screws(use the size that fits your junction box)(2) Tornillos #6 y (2) tornillos #8 de montaje (utilice eltamaño que mejor se adecue a su caja de conexión)(2) vis nº 6 et (2 )vis nº 8 pour boîte de jonction (choisissezla dimension convenant à votre boîte de jonction)C. (3) Wire nuts(3) Conectores del cables(3) Capuchons de connexionE. (2) Reflectors(2) Reflectores(2) réflecteursMS245RW (White) |
Related manuals for Eaton All-Pro MS245R
Eaton All-Pro MS180 Instruction Manual
Eaton ALL-PRO MS185DW Instruction Manual
Eaton All-Pro MS180BT Instruction Manual
Eaton HALO MS180 Instruction Manual
Eaton HaloHome MST20C18W Instruction Manual
Eaton DET-REXT-PIR30 Installation Instructions Manual
Eaton Sure-Lites 2C Installation Instructions Manual
Eaton Sure-Lites UX6 Installation Instructions Manual
Eaton Cooper Power Series Installation Instructions Manual
Eaton RLF 25 Series Operating Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine