600 A 15/25 and 35 kV class deadbreak protective cap installation instructions1 INSTALLATION INSTRUCTIONS MN650054EN May 2017WARNINGHigh Voltage All associated apparatus mustbe de-energized during installation, removal ormaintenance Failure to comply could result in death,severe personal injury and equipment damageCAUTIONThe Eaton Cooper Power series 600 A DeadbreakProtective Cap Assembly is designed to be operatedin accordance with normal safe operating proceduresThese instructions are not intended to supersede orreplace existing safety and operating proceduresTerminators must be de-energized during operation ormaintenance Visible break and adequate groundingmust be provided before cable work proceeds(Ensure that the connector is rated for the intendedapplication before it is installed )The Deadbreak Protective Cap Assembly should beinstalled and serviced only by personnel familiar withgood safety practice and the handling of high-voltageelectrical equipmentProduct informationIntroductionThe 600 A Deadbreak Protective Cap meets the fullrequirements of IEEE Std 386™ standard — SeparableInsulated Connector Systems, and provides an insulated,fully shielded and submersible protection for energizeddeadbreak interfaces. The cap is required for temporary orpermanent installation on deadbreak bushings, junctionsand other accessories having interfaces that conform toIEEE Std 386™ standard.Read this manual firstRead and understand the contents of this manual and followall locally approved procedures and safety practices beforeinstalling or operating this equipment.PULLING EYEDRAIN WIREFigure 1 Standard insulated protective cap(15/25 kV shown)Additional informationThese instructions cannot cover all details or variationsin the equipment, procedures, or process described norprovide directions for meeting every possible contingencyduring installation, operation, or maintenance. For additionalinformation, contact your Eaton representative.Acceptance and initial inspectionEach 600 A Deadbreak Protective Cap is in good conditionwhen accepted by the carrier for shipment. Upon receipt,inspect the shipping container for signs of damage. Unpackthe Deadbreak Protective Cap and inspect it thoroughly fordamage incurred during shipment. If damage is discovered,file a claim with the carrier immediately.Handling and storageBe careful during handling and storage of the DeadbreakProtective Cap to minimize the possibility of damage. If theDeadbreak Protective Cap is to be stored for any length oftime prior to installation, provide a clean, dry storage area.StandardsISO 9001 Certified Quality Management System