Eaton EPCT Fire Series Installation Manual
11ProgrammingEPCT FirE sEriEs FirE PumP ConTrollEr MN124016EN August 2019 www.eaton.com5.0 Programming5.1 IntroductionThe EPCT controller is fully programmable from the device’sfaceplate. Users can program set points as well as otherparameters. The time, date, and set points can only bechanged from the menu system.The menu system is broken down to tab systems. Theseinclude, Home, Startup, Panel Setup, Help, PressureSettings, Timer Values, ATS Settings (if equipped), AlarmSetpoints, Inputs/Outputs, History/Statistics/Diagnostics,and Optional Output Card(s) (if equipped).5.2 NavigationIn order to navigate through the EPCT operating system,press the tabs at the top of the screen to go through themenu. If the main menu password is enabled, the user willbe prompted to enter the password to access any of thetabs except for Help and History/Statistics/Diagnostics.NOTICEIt is recommended to set up a main menu password to helpprevent any unauthorized access to the controller. This willhelp prevent reprogramming the controller that will impedethe operation of the fire pump controller.The controller does come with the ability to “Lockout” thedisplay after thirty (30) minutes of inactivity to minimizeaccidental inputs. This feature will not inhibit the normaloperation of the controller. To unlock the display, the userwill be prompted to enter in “EPCT”.In order to increase the longevity of the display board,the controller will activate the screensaver after thirty (30)minutes of inactivity. The screen saver will turn the screenblack and will show a moving EATON logo. To deactivate thescreensaver simply press anywhere on the screen.All EPCT controller programmable features and associatedset-point possibilities are presented in Table 1.Table 1Description rangePanel setupLanguage English / French / Spanish / Portuguese / Turkish/ Italian / Polish / Simplified Chinese / DutchSet time 24 HoursSet date Any valid dateSet day of the week Any valid day of the weekStarting method Across the Line / Part Winding / PrimaryResistor / Autotransformer/ WYE-Delta Open /Wye-Delta Close / Soft StartSingle phase start Enabled / DisabledAuto shutdown Enabled / DisabledMotor HP 0-9999 HPNominal voltage 200-7200VPhases Single Phase / Three PhaseDescription rangeSystem Frequency 50Hz / 60HzCT Ratio 50:0.1 / 100:0.1 / 150:0.1 / 300:0.1 / 500:0.1 /800:0.1 / 1200:0.1Motor FLA 1-999 AFoam Controller Enabled / DisabledMenu Password One (1) to seven (7) digit numeric / DisabledController Serial Number Standard keyboard entry with space for fifty (50)digits - Numeric and/or Alphabetical -Pump Serial Number Standard keyboard entry with space for fifty (50)digits - Numeric and/or AlphabeticalScreen Brightness 20%, 40%, 60%, 80%, 100%Enable Welcome Screen Enabled / DisabledScreen Lock Enable/DisableCustomer service contactEnable Password Protection One (1) to seven (7) digit numeric / DisabledCompany Name Standard keyboard entry with space for fifty (50)digits - Numeric and/or AlphabeticalContact Name Standard keyboard entry with space for fifty (50)digits - Numeric and/or AlphabeticalPhone Number Numeric entry with space for 15 digitsEmail Standard keyboard entry with space for fifty (50)digits - Numeric and/or Alphabeticalservice message triggerNumber of Hours Run 1-999 HourNumber of Starts 1-999 Pump RunsSpecific Time and Date 24 Hours - Any valid dateDe-energize Common Alarm Enabled / DisabledPressure settingsStart Pressure 0-999 PSI / DisabledStop Pressure 0-999 PSI / DisabledLow Pressure Alarm 0-999 PSI / DisabledHigh Pressure Alarm 0-999 PSI / DisabledStart Above Pressure 0-999 PSI / DisabledPressure Variance Recording 1-999 PSI / DisabledHourly Pressure Recording Enabled / Disabledlow suction shutdown Enabled / DisabledShutdown Delay 0-99 Seconds / DisabledReset Mode Automatic / ManualAutomatic Reset Delay 0-99 Seconds / Disabledlow foam shutdown Enabled / DisabledShutdown Delay 0-99 Seconds / DisabledReset Mode Automatic / ManualAutomatic Reset Delay 0-99 Seconds / DisabledProof Pressure Switch Enabled / DisabledPressure Units PSI / BAR / kPaPressure Transducer Enabled / DisabledCalibrate PressureTransducer Calibrate Using 0 PSI / Calibrate Using CurrentPressure / Reset to Factory DefaultTimer valuesMinimum Run Time Four (4) digit numeric entry in Minutes:Seconds / DisabledAcceleration Timer 0-10 seconds / DisabledSequential Start Timer 0-999 seconds / DisabledFail to Start Timer 0-999 seconds / Disabled |
Related manuals for Eaton EPCT Fire Series
Eaton MMX11 Series Installation Instructions Manual
Eaton SFX Series Installation And Operation Manual
Eaton HFX Series Installation And Operation Manual
Eaton SCD24 Installation Manual
Eaton WaveLinx series Installation Instructions Manual
Eaton CGLine+ CGVision Series Quick Installation Manual
Eaton EFX48 e-Fuse Series Installation And Operation Manual
Eaton OPTE9 Installation Manual
Eaton S811 Quick Installation Manual
Eaton DILE Series Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine