To check calibration or to recalibrate the machine,• Navigate to the Product Library.• Select CALIBRATION spec and load it into the machine.• Navigate to the production screen and crimp a TTC/Z series -8 fittingwith an M240 die.• Log in as admin.While on the Maintenance screen,• Select the calculator icon. The calculator window will open.• Enter the FOUR MEASUREMENTS and select the Calculate button.The offset value is automatically calculated and stored.Note: The calculated offset may be adjusted and overwritten byselecting the Offset button and entering a new value. Note - Validvalues are between 0.900 and 1.100. Do not include decimalpoints when entering. Examples: 0900, 1100Note: The calculator icon only appears when the CALIBRATION spec is loaded.Any additional offset is calculated and added to original offset value.Re-check an additional -8 TTC/Z series fitting and repeat as required.Machine Calibration