The RESTORE option brings up a menu to load the new software,to load your current saved program, or to load your favorites list.To restore your favorites after a software update:• First backup all files.• Then backup the favorites list.• Next, restore all factory crimper files.Then restore the favorites list.Select Exit to close the utility and use the crimper.To install new updates without restoring favorites:• First backup all files.• Next, restore all factory crimper files.Select Exit to close the utility and use the crimper.If there is a problem with the new program use the USB utility to restoreall your files to their previous state.*Note – offsets will need to be re-entered and verified.PLC UpdatesIn the event that a PLC update is required, a micro-SD memorycard (SD or SDHC) with a capacity of 128 MB to 32 GB is required.To perform update:1. With the machine turned off, open theelectrical box and locate the PLC.2. Open the drawer on the left side of the PLC andinsert the micro-SD card.3. Close the SD card drawer.4. Turn on the machine. Updates willinstall automatically.5. After updates complete, turn off the machine.6. Remove the micro-SD card from the PLCand close the electrical box.7. Proceed with HMI update using the providedUSB drive as described above.Updating software (cont.)GO BACK TO MAIN MENUEATON FT1380E USB UTILITY - RESTORE MENURESTORE ALL YOUR FILESFACTORY RESET - RESTORE ALL ORIGINAL EATON FT1380E FILESRESTORE YOUR FAVORITES LIST