2EATON IB500014EN Installation instructionsInstallation Instructions – CaretakerWall/Pole MountTools Required: 1/2” Socket wrench, 7/16” Socket wrench,drill, 3/16” drill bit.1. Use a 1/2” socket wrench to remove wall/pole mountbracket from fixture and set aside two fixture mountingbolts and wire shield. Discard pipe clamp bracket.(Figure 1.)2. Determine mounting surface.●● Wall/Square Pole Mount: Place bracket (wall/sq polemount) face against mounting surface with bracketarrow pointing up. (Figure 2.)●● Wood Pole Mount: Place bracket (wood pole mount)face against pole with bracket arrow pointing up.(Figure 3.)3. Using 7/16” socket, drive four lag bolts (provided)where indicated. Tighten bolts to approx. 6-8 ft-lbs.ote:N Ensure provided lag screws are compatible withanchor material and anchor material is capable ofwithstanding required torque.ote:N Do not use holes labeled “luminaire” to fastenbracket to mounting surface.4. With supply wires pulled through 1/2” conduit hole6” to 8”, slide fixture down over bracket and ensuresupport tab is correctly positioned inside the housingwall cavity.5. Using 1/2” socket, install wire shield as shown withtwo fixture mounting bolts up through the wall/polebracket and into luminaire. If connection to conduit holein the bottom of mounting bracket is preferred, removethe knockout tab on the wire shield. Tighten to 6-8ft-lbs.(Figure 4 and 5.)Figure 1.Figure 2.Figure 3.Figure 4.Figure 5.Support TabSupport Tab1/2” Conduit Hole1/2” Conduit Hole(4) 1/4” X 2”Long Lag Bolts(4) 1/4” X 2”Long Lag Bolts(2) Mounting BoltsUniversalBracketPipe ClampWire Shield(2) MountingBoltsKnockout In WireShield For ConduitConnection(2) Mounting BoltsKnockout In Wire Shield ForConduit Connection