5EATON IB500014EN Installation instructionsInstallation Instructions – CaretakerFigure 12.Figure 13.(3) O-Ring Screw Retainers(3) #8-32 X 3/8” ScrewsDrop House Side ShieldOptional Drop Shield House Side ShieldTools Required: 1/4” Socket or flathead screw driver.1. Insert provided thread forming screws into house side shield mounting locations and place provided O-rings over screwthreads to hold screws within House Side Shield. Install house side shield onto housing. (Figure 12.)ote:N There are four positions for the House Side Shield at 90° increments.Optional Drop Shield House Side Shield with SRRefractorTools Required: 1/4” socket or flathead screwdriver.1. If using the Drop House Side Shield with the SRRefractor, slide the drop house side shield in thedesired position within the SR refractor.2. Insert provided thread forming screws into refractorand house side shield and place provided O-rings overscrew threads to hold screws within Drop House SideShield and SR Refractor.3. Install SR refractor in the die-cast housing in the twoside mounting locations. (Figure 13.)MAINTENANCE NOTE: A regular maintenance scheduleshould be followed to retain optimal light output andthermal performance. Optical lens cleaning should beperformed with a clean dry cloth to remove any dust orother contaminants. Additional cleaning can be performedwith non-abrasive cleanser.SR RefractorO-Ring ScrewRetainerDrop House SideShield (Optional)#8-32 X1/2” Screws