Analogue time switch 24 hAnalog-Zeitschaltuhr 24 hMinuterie analogique 24 hInterruttore orario analogico 24 hInterruptor horario analógico 24 hInterruptor horário analógico 24 hAnaloge schakelklok 24 hAnalogowy zegar sterujący 24 hTSSD1CO 167391TSQD1CO 167390TSQD1CONL1L1/L2/L316(4) 250~R200h (230V)R100h (110V) 110–230V~ –20T50–60Hz1 2 3TSQD1CO1810822GB D F IE P NL PLService address/HotlineEaton Industries (Austria) GmbHScheydgasse 42A-1215 Wienwww.eaton.com309517Basic safety instructionsDesignated use• The time switch can be used for lighting, ventilation, fountains,advertising hoardings etc.• Only for use in closed, dry rooms• Installation on DIN top hat rail (in accordance with DIN EN 60715)DisposalDispose of device in environmentally sound mannerDanger of death through electric shock or fire! Installation should only be carried out by a qualified electrician!WARNINGe.g. 3:00 (morning) e.g. 6:15–10:45; 16:15–21:00 ON21:0016:156:1510:45e.g. 15:00 (afternoon)Set time Set switching timesENGLISHDescription Switching pre-selection/manualsetting Program timing disc Switching segments (1 = 15 mins) Morning/afternoon(AM/PM) time display Hand for setting time (hours andminutes) can be adjusted anti-clockwise and clockwise; turnminute hand firmly to left Three way switch:Permanent ON – AUTO –Permanent OFFin advance 3:00 ON (= 1)Set manual operation/switching pre-selectionSet 1 – n – 0 permanentswitching= 1Program is not operated.1 = Permanent ON0 = Permanent OFFThe time switch operates the set swit-ching times, i.e. it returns to program.n 1Connection, technical data see on the back sideConnection/installationWarning, danger of death through electricshock! Must be installed by qualified electrician! Disconnect power source! Cover or shield any adjacent live components. Ensure device cannot be switched on! Check power supply is connected! Earth and bypass!for TSQD1CO only Quarz movement only starts in a few minutesafter power is switched on. Full power reserve is achieved after approx.5 days.WARNINGKlick45°8 mm45°8 mmTSSD1CO TSQD1COOperating voltage: 230 V~, +10 %/-15 % 50 Hz 110–230 V~, 50–60 HzPower consumption: max. 1 VA max. 1 VASwitching contact: floating (not for SELV/PELV) floating (not for SELV/PELV)Contact: two-way switch two-way switchGap: <3 mm (μ) <3 mm (μ)Contact material: Ag AgSwitching capacity: 16 A, 250 V~, cos ϕ = 1 16 A, 250 V~, cos ϕ = 14 A, 250 V~, cos ϕ = 0,6 4 A, 250 V~, cos ϕ = 0,6Incandescent lamp load: 1100 W 1100 WFluorescent lamp load: parallel-corrected parallel-corrected2 x 40 W (4,7μF) 2 x 40 W (4,7μF)Perm. ambient temperature: –20 °C ... +55 °C –20 °C ... +55 °CProtection class: II in acc. with EN 60730-1 for II in acc. with EN 60730-1 fordesignated installation designated installationProtection rating: IP 20 in accordance with EN 60529 IP 20 in acc. with EN 60529Time accuracy: synchronised with mains ≤ ±1 s/s day at +20 °CPower reserve: – – R 200 h (230 V), R 100 h (110 V)Pollution degree: 2 2Type: 1 BRTU 1 BSTUTechnical Data