xChargeIn M Series MaintenanceConfiguration manual V1.04 87© EATON6 Maintenance6.1 Diagnosis and troubleshootingThe FAQs on our website help to rectify possible errors that might occur:www.eaton.com/evc6.2 Software updateIt is recommended to always keep the charging station up-to-date, as it con-tains functional enhancements and bug fixes. A software update is availableon our website:www.eaton.com/evcThe information and instructions for the current software package from theassociated release notes must also be observed.A software update may only be performed if no vehicle is plugged in at thecharging station.InformationThe software update can take up to an hour. The update process is indi-cated by a slow orange flashing of the LED bar.After the software update, the charging station restarts automatically. TheLED bar will flash blue or green, depending on the authorization setting.InformationThe power supply must not be interrupted during the software update. Oth-erwise, the software update is not terminated correctly and further normaloperation of the charging station is no longer guaranteed.Software update at charging networkA software update for a charging network must be performed at the mastercharging station (xChargeIn M Series). The master charging station relaysthe new firmware to the connected slave charging stations (S Series) via thesoftware update.