16Entrapment protectionTo comply with the UL325 standard for gate operators everyentrapment zone, as defined in ASTMF2200, must be pro-tected by two independent entrapment protection devices.One of the devices is inherent in the FAAC operators or thecontrol board design, the other can be external, like a pho-tocell or an edge sensor.See the following picture for the photocells positioning:Closing Safety Devices Opening SafetyDevicesOpening Safety Devices:Are active only during the gate opening movement, andare suitable for protecting the area between the openingleaves and fixed obstacles (walls, etc) agains the risk ofentrapmentClosing Safety Devices:Are active only during the gate closing movement, and aresuitable for protecting the closing area against the risk ofentrapment.Monitored Devices:Additionaly the UL325 standard requires that every externalentrapment protection device must be monitored forpresence and correct operation. The closing safety devicesare always monitored, see the following picture for the wiringof a pair of photocells as closing safety devices.NOTE: one closing safety device must always be connectedfor the system to work.1254312RX CL TX CL9 10 11 12 13 14 15 16 17 18 19OPENA B STP CL OPFSW - - - +24V+ + -TXFSW20 21W.L. LOCK-+-+1254312RX OP TX OP-+-+-+-+++1254312RX CL TX CL9 10 11 12 13 14 15 16 17 18 19OPENA B STP CL OPFSW - - - +24V+ + -TXFSW20 21W.L. LOCK-+-+-+ +Connection of One Pair of Monitored ClosingPhotocells and One Pair of Monitored OpeningPhotocellsConnection of One Pair of Monitored Closing PhotocellsF ++ADVANCED PROGRAMMINGOPENING FAIL SAFE:If this function is activated, it enables themonitoring of the opening safety photocellbefore he opening movement. If the test failsthe gate does not open.= Active = DisabledDisplay Function DefaultMonitoring of the opening safety devices must be enabledin the board configuration. To enable it enter in advancedprogramming by pressing and holding “F” and then press“+”, scroll to the “FS” parameter and select “Active”.6. Connection of Safety devices16” or lessIf an additional monitored opening safety device isneeded it can be connected to the STP input. The “OP”parameter in the board configuration must be set to active12TX OP 29 10 1 12 13 14 15 16 17 18 19OPENA B STP CLOPFSW- - -+24V+ +-TXFSW2021W.L.LOCK-+54312RX OP 2-+-+ +1OPENING No. 2 FAIL SAFE:When enabled the STOP input can be used forthe connection of a second monitored openingsafety device.= Active = Disabled