1 ¼ 6 784) Install a 1-1/4" PVC conduit for the hydraulic lines that reachesthe hydraulic control unit (fig.6).The path of the conduit must have wide bends to facilitate therouting of the hydraulic lines (fig.7).5) Place the drive unit on the foundation plate as shown in fig.5/a-b, and ensure that it is not resting on the levelling setscrews (fig.2 - ref.7).Make sure that the center of the splined shaft is verticallyaligned with the center of the gate hinge axis (use a plumbline)6) Place the provided C-brackets at the base of the drive unitand weld directly to the foundation plate as shown in fig.8.Do not weld the base of the jack to thefoundation plate or to the C-bracket.7) Prepare the two L-shaped "box halves" for installation. Notethat the lip on each piece shouldbe on top so as to supportthe top cover. Make the necessary holes for the two hydrauliclines that run from the drive unit to the power unit8) Weld the box halves to the foundation plate and to one anotherso as to enclose the drive unit on four sides. Be sure to protectthe drive unit during welding.2.3 INSTALLING THE HYDRAULIC CONTROL UNIT1) Place the control unit box as close as possible to the drive unit.The maximum distance is 65 ft (20 m). The box can be surfacemounted to a wall (fig.10) or recessed (fig.11).If you recess thebox, keep in mind that hydraulic hoses and electrical wiringneed to enter from the bottom2) The control unit box ships with hinges on the left, but theopening can be reversed if necessary To reverse the openingdirection, open the cover, and then gently pull it off the box.The hinges can now be placed in the hinge receptacles onthe right-hand side. Be extremely cautious when doing thisto avoid damaging the hinges. Secure the hinges with thescrews provided.3) Route the electical cable and hdraulic lines using the 4 knock-out holes on the bottom.9 5/813 7/82 1/25 1/23 3/1698