Technical DataThe 750 Operator 750 Standard 750 Long Leaf 750 Extra Long LeafAmbient temperature, deg F (deg C) -13 to 158 (-25 to 70)Maximum duty cycle 30 Cycles/ HourThermal cut out, deg F (deg C) 212 (100)Power voltage required, VAC* 115 ±10% or 230, +6 or -10%, 60 Hz 230, +6 or -10%, 60 HzAbsorbed power, W 220Motor speed, rpm 1400 960Type of oil Lubrication Engineers ñ MONOLEC 6105Hydraulic Power Unit:Height × width × depth, in. (cm) 13 3 /4 × 8 3 /16 × 5 1 /8 (35 × 20.8 × 13)Weight, lb (kg) 20 (9)Oil quantity, qt (l) 1 (0.9)Hydraulic locking: CBC: ClosedCBAC: Openedand closedNot available Not availableGate weight, lb (kg) 1760 (800)Maximum gate length, ft (m) 7 (2.1) 10 (3) 13 (4)Hydraulic Drive Unit:Height (not including shaft) ×length × width, in. (cm) 4 7/8 × 15 3 /4 × 7 7/8 (12.4 × 40 × 20)Weight100-deg swing, lb (kg)180-deg swing, lb (kg)18 (8)20 (9)Oil quantity, qt (l) 0.9 (1)Maximum angle of rotation100-deg swing, deg180-deg swing, deg11820090-deg opening time, sec 12 17Nominal torque, ft-lb (Nm) 338 (460)* Your standard 220 VAC power source meets the specification for 230 VAC, +6 or -10%.The Control PanelThe 750 Operator must be installed with a 450 MPScontrol panel to be a U.L. recognized installation. The450 MPS can be used to control a single 400 operator ora dual (biparting) system. Both the control panel andthe operator must use the same power supply voltage.The 450 MPSTo determine the voltage requirement of your 450 MPScontrol panel, refer to the label on the transformer of thecontrol panel:Label reads: 450MPSUS = 220 VAC450MPSUS115 = 115 VACOperating logics available: E, EP, A, S, B, and C